6One of the simplifying assumptions we make in this derivation is that friction plays no significant role in the fluid’s behavior as it moves through the venturi tube. In truth, no industrial fluid flow is totally frictionless (especially through more primitive flow elements such as orifice plates), and so our “theoretical” equations must be adjusted a bit to match real life.